Technical Specifications: Training Contents:  Single Phase Transformer:  Measurement of the single-phase transformer ratio and parameter by no-load and short circuit experiment  rawing out of the T type equivalent circuit di...



SPECIFICATION

Technical Specifications:
Training Contents:

  •  Single Phase Transformer:
  •  Measurement of the single-phase transformer ratio and parameter by no-load and short circuit experiment
  •  rawing out of the T type equivalent circuit diagram according to parameters to be measured from no-load and short circuit experiment
  •  Measurement of the running characteristic of transformer by resistive / inductive /capacitive load experiment
  •  Parallel operation of transformer (polarity discrimination, parallel two transformers)
  •  Three Phase Transformer:
  •  High / Low voltage winding discrimination, primary / secondary polarity measurement
  •  Measurement of the three-phase transformer ratio and parameter by no-load and short circuit experiment
  •  Three phase transformer Y-Y12 connection
  •  Three phase transformer Y-Y6 connection
  •  Three phase transformer Y-Δ11 connection
  •  Three phase transformer Y-Δ5 connection
  •  Voltage vector diagram of three phase transformer under different connections
  • Features and Technical Specification:
  •  This trainer should be designed to meet the operational training of electrical transformer, covering a variety of training topics for single phase and three phase characteristics, as well as parametric measurement
  •  The frame should adopt standard aluminum profile with modular experiment panel design, thus, making it easy to build different experiment combination on the flexible twolayer structure
  •  All the upper parts should be removable including the experiment module, power supply module and frame support
  •  All terminals should led out on printed composite panel with 4mm safety socket and connected by full sealing sheathed pluggable connector
  •  The complete unit should be movable with lockable truckles on bottom
  •  Mobile aluminium experiment stand:
  •  High compressed chipboard tabletop & baseplate
  •  Solid impact-resistant protective edging
  •  Minimum 6 extruded aluminium profiles with 8 grooves
  •  Minimum 3 H-shaped profiles for panel organization
  •  4 swivelling casters, 2 have brakes
  •  Table & upper frame part are separable for easy delivery
  •  Cable holder should be attached to side column for at least 48 cable pcs
  •  Three phase power supply:
  •  RCCB and momentary pushbutton with lamp, green / red
  •  Key switch, 1NO/NC and AC contactor
  •  Input CEE socket, output 4mm safety socket
  •  Three phase voltage regulators:
  •  1KW regulator, 0 ~ 450V, 0 ~ 250V variable output
  •  Indicating lamp R/G/Y
  •  Output voltage monitoring meter x3
  •  Selective input and output voltage display
  •  Single phase transformer 1.0:
  •  PN = 77W, UN = 220V/55V, IN = 0.35A/1.4A
  •  Transformer x3
  • With all terminals led to colorized 4mm safety socket
  • Three phase transformer 1.0:
  •  PN = 200W, UN = 220V/55V, IN = 0.52A/2.09A
  •  With all terminal led to colorized 4mm safety socket
  •  Power & Power factor meter 1.0:
  •  Single phase active power meter, digital, 0 ~ 1000W x2
  •  Power factor meter, digital, 380V/5A
  •  With all terminal led to colorized 4mm safety socket
  •  AC voltmeter & AC ammeter 2.0:
  •  Voltmeter digital AC 0 ~ 450V x3
  •  Ammeter digital AC 0 ~ 3A x3
  •  With all terminal led to colorized 4mm safety socket
  •  Standard size available for frame insertion
  •  Capacitive load 1.0:
  •  Fuse protector 3A x 3
  •  3-fold capacitors of 1uF/2uF/4uF/6uF
  •  With all terminal led to colorized 4mm safety socket
  •  Inductive load 1.0:
  •  Auto former regulator 0 ~ 250V with fixed inductor group x3
  •  Inductance value 1H, adjustable, 0.48A
  •  Fuse protectors x3
  • With all terminal led to colorized 4mm safety socket
  •  Resistive load 1.0:
  •  Double-linked resistor x3
  •  Each with variable range 0 ~ 900Ω, 0.41A
  •  Fuse protector x6

Accessories:

  •  Safety whole sealing cable: conductor cross section: 16AWG tinned copper wire, 3kV, 20A, with axial socket
  •  Experiment guidebook
  •  Wiring instruction map
  •  Warranty: 1(One) year with services
  •  Documents: Manufacturer's Authorization Letter with contact details should be submitted
  •  ISO Certificate and Catalogue should be submitted
  •  Installation, Testing and Commissioning: Should be performed by bidder’s qualified and experienced engineers
  •  Training: Training by bidder’s qualified and experienced engineers at DTTTI premises should be provided